|
网络模块 |
|
Ethernet Network Adapter, Modbus/TCP | |
|
RS-485 Network Adapter, Modbus/RTU | |
|
RS-232 Network Adapter, Modbus/RTU | | | |
|
数字输入 |
4/8 通道, 24/48 VDC 数字输入模块 |
|
4 Digital inputs, sink, 24 VDC, RTB | |
|
4 Digital inputs, source, 24 VDC, RTB | |
|
8 Digital inputs, sink, 24 VDC, RTB | |
|
8 Digital inputs, source, 24 VDC, RTB | |
|
4 Digital inputs, sink, 48 VDC, RTB | |
|
4 Digital inputs, source, 48 VDC, RTB | | | |
16 通道 , 24 VDC 数字输入模块 |
|
16 Digital inputs, sink, 24 VDC, 20 pins | |
|
16 Digital inputs, source, 24 VDC, 20 pins | | | |
4 通道, 110V/240 VAC 数字输入模块 |
|
4 Digital inputs, 110 VAC, RTB | |
|
4 Digital inputs, 220 VAC, RTB | | | |
|
数字输出 |
4/8 通道, 24/48 VDC 数字输出模块 |
|
4 Digital outputs, sink, MOSFET, 24 VDC, 0.5A, RTB | |
|
4 Digital outputs, source, MOSFET, 24 VDC, 0.5A, RTB | |
|
8 Digital outputs, sink, MOSFET, 24 VDC, 0.5A, RTB | |
|
8 Digital outputs, source, MOSFET, 24 VDC, 0.5A, RTB | | | |
4 通道数字输出模块,带自我检测 |
|
4 Digital outputs, sink, MOSFET, self-diagnostics, 24 VDC, 0.5A, RTB | |
|
4 Digital outputs, source, MOSFET, self-diagnostics, 24 VDC, 0.5A, RTB | |
|
4 Digital outputs, sink, MOSFET, self-diagnostics, 24 VDC, 2.0A, RTB | |
|
4 Digital outputs, source, MOSFET, self-diagnostics, 24 VDC, 2.0A, RTB | | | |
16 通道数字输出模块 |
|
16 Digital outputs, sink, MOSFET, 24 VDC, 0.3A, 20 pins | |
|
16 Digital outputs, source, MOSFET, 24 VDC, 0.3A, 20 pins | | | |
2 通道继电输出模模块 |
|
2 Digital outputs, relay, 24 VDC/230 VAC, 2.0A, RTB | |
|
2 Digital outputs, Triac, 12 to 125 VAC, 0.5A, RTB | | | |
|
模拟输入 |
一般解决方案 |
|
4 Analog inputs, Current, 0 to 20 mA, 12-bit, RTB | |
|
4 Analog inputs, Current, 4 to 20 mA, 12-bit, RTB | |
|
2 Analog inputs, Voltage, 0 to 10V, 12-bit, RTB | |
|
2 Analog inputs, Voltage, -10 to 10V, 12-bit, RTB |
|
4 Analog inputs, Voltage, 0 to 5V, single-ended, 12-bit, RTB |
| | |
高级解决方案 |
|
4 Analog inputs, Current, 0 to 20 mA, 14-bit, RTB | |
|
4 Analog inputs, Current, 4 to 20 mA, 14-bit, RTB | |
|
4 Analog inputs, Voltage, 0 to 10V, 14-bit, RTB | |
|
4 Analog inputs, Voltage, -10 to 10V, 14-bit, RTB | |
|
4 Analog inputs, Voltage, 0 to 5V, single-ended, 14-bit, RTB | | | |
|
模拟输出 |
|
2 Analog outputs, 0 to 20 mA, 12-bit, RTB | |
|
2 Analog outputs, 4 to 20 mA, 12-bit, RTB | |
|
2 Analog outputs, Voltage, 0 to 10V, 12-bit, RTB | |
|
2 Analog outputs, Voltage, -10 to 10V, 12-bit, RTB | |
|
2 Analog outputs, Voltage, 0 to 5V, 12-bit, RTB | | | |
|
温度模块 |
|
2 Analog inputs, RTD:PT100, JPT100, RTB | |
|
2 Analog inputs, Thermocouple: 30 mV (1 μV/bit) , RTB | | | |
|
系统模块 |
|
System expansion power supply, 1.0A/5 VDC | |
|
Field power distributor, 10A (24/48 VDC, 110/220 VAC) | |
|
Potential Distributor, 8-ch, Shield signal | |
|
Potential distributor, 8-ch, 0 VDC | |
|
Potential distributor, 8-ch, 24 VDC | |
|
Potential distributor, 4-ch/24 VDC, 4-ch/0 VDC | | | |
|
附件 |
|
Removable Terminal Block, 9 pcs per pack | |
|
Marker with 0 to 9 numbering, white color, 100 pcs | |
|
| | |